Hyperscale AI Data Center Design-Build Solutions

ESDMC provides design-build solutions for next-generation AI data center facilities engineered to support ultra-high-density compute environments, advanced cooling architectures, and mission-critical uptime requirements. We specialize in facilities designed for AI/ML workloads, GPU clusters, and accelerated computing, where rack densities, thermal loads, and power infrastructure significantly exceed traditional data center benchmarks.

Built for the Next Generation of Compute

AI-driven infrastructure is redefining data center design parameters:

  • Rack densities moving from 10–20 kW (traditional) to 80 kW – 300+ kW per rack
  • Campus-scale deployments exceeding 100MW+ critical load
  • Increasing reliance on liquid cooling (direct-to-chip and immersion)
  • Higher demands on power quality, redundancy, and thermal stability

ESDMC aligns design and construction execution with these realities—bridging the gap between conceptual engineering and field-level constructability to deliver facilities that perform under sustained, high-output compute loads.

Core Capabilities

Site Selection, Power Strategy & Feasibility

  • Utility capacity analysis (substation proximity, redundancy options, dual-feed viability)
  • Evaluation of available MW capacity and interconnection timelines
  • Land planning for phased campus deployments
  • Flood zone, elevation, and resiliency planning (critical for coastal and hurricane-prone regions)
  • Fiber access, latency considerations, and carrier diversity

Mission-Critical Design Coordination

  • Integrated coordination across civil, structural, architectural, mechanical, electrical, and controls
  • Planning for Tier III / Tier IV-equivalent resiliency strategies
  • Space planning for high-density data halls, support infrastructure, and future expansion
  • Structural coordination for high floor loading and equipment density
  • BIM-driven clash detection and constructability validation

High-Density Cooling Infrastructure

  • Design-build execution for liquid cooling-ready environments, including:
    • Direct-to-chip liquid cooling systems
    • Rear door heat exchangers
    • Immersion cooling readiness (single-phase / two-phase)
  • Coordination of:
    • CDU (Coolant Distribution Units)
    • Secondary fluid loops
    • Heat rejection systems (cooling towers, dry coolers, hybrid systems)
  • Integration of hot aisle / cold aisle containment and hybrid air/liquid strategies
  • Mechanical redundancy
  • Optimization for PUE reduction and thermal efficiency under variable AI loads

Electrical Infrastructure & Power Distribution

  • Utility-to-rack power architecture including:
    • Medium voltage distribution
    • Switchgear and paralleling gear
    • Generators and fuel systems (diesel / alternative fuels)
    • UPS systems (centralized and distributed architectures)
  • Design and construction for high-density rack distribution:
  • Redundancy strategies:
  • Power quality and harmonics mitigation for AI workloads
  • Future-proofing for increasing rack densities and evolving hardware requirements

Design-Build Delivery Model

  • Single-source accountability from pre-construction through commissioning
  • Early procurement strategies for long-lead equipment:
    • Switchgear
    • Generators
    • Cooling systems
  • Phased turnover for accelerated deployment of data halls
  • Reduced risk through early trade partner integration

Commissioning & Operational Readiness

  • Level 1–5 commissioning coordination
  • Integrated systems testing (IST)
  • Functional performance testing of:
    • Electrical systems
    • Mechanical systems
    • Controls and monitoring systems
  • QA/QC processes aligned with mission-critical standards
  • Documentation, training, and turnover protocols for operations teams

Why team with us?

  • Purpose-built for AI and high-performance computing environments
  • Experience coordinating complex MEP systems at scale
  • Strong focus on constructability in high-density environments
  • Design-build model optimized for speed to market
  • Ability to execute in phased, live, or expansion environments
  • Deep understanding of thermal, electrical, and spatial constraints in AI facilities